The authors regret that we found several minor errors in the background material of the manuscript. These errors do not affect the results and the outcome of the study. The following list is the changes that we would like to fix to the published manuscript: Section 1: Introduction (page 334) “in the second paragraph”: • Original manuscript: “In Canada, about 16% of the 135 PJ that are allocated to commercial and institutional buildings is used for educational facilities.”Revised: “In Ontario, about 12.5% of the 384.9 PJ that are allocated to commercial and institutional (C&I) buildings is used for educational facilities.” • Original manuscript: “GHG emissions for Ontario educational facilities were estimated to be 170.8 megatonnes of carbon dioxide equivalent (CO2e) in 2013, out of which 8.73 megatonnes (82.2 kg CO2e/m2) were allocated for universities.”Revised: “GHG emissions for Ontario were estimated to be 170.2 megatonnes of carbon dioxide equivalent (CO2e) in 2014, out of which 18.13 megatonnes, 2.27 megatonnes, and 0.89 megatonnes (82.2 kg CO2e/m2) were allocated for the C&I sector, educational facilities, and universities, respectively.” Table 2 CO2e Emission Factors (page 339): • Original manuscript: Electricity CO2e Emission Factor is 0.0236 kg CO2e/MJ.Revised: Electricity CO2e Emission Factor is 0.014 kg CO2e/MJ. • Original manuscript: Bio-fuel CO2e Emission Factors are 0.09 kg CO2e/MJ and 0.324 kg CO2e/kWh.Revised: Bio-fuel CO2e Emission Factors are 0.0083 kg CO2e/MJ and 0.03 kg CO2e/kWh. • Original manuscript: The units in the table for the CO2e Emission Factors are kg CO2e/MJ and kgCO2e/kWh.Revised: For electricity, the units should be CO2e/MJelectrical and kg CO2e/kWhelectrical. For natural gas and Bio-fuel, the units should be CO2e/MJthermal and kg CO2e/kWhthermal. Reference number [5] is replaced with a new reference. Natural Resources Canada (NRCan), “Commercial/Institutional Sector – Ontario”, Natural Resources Canada (NRCan), 2016. [Online]. Available: http://oee.nrcan.gc.ca/corporate/statistics/neud/dpa/menus/trends/comprehensive/trends_com_on.cfm. [Accessed 5 April 2017]. The authors would like to apologise for any inconvenience caused.

Additional Metadata
Persistent URL dx.doi.org/10.1016/j.enbuild.2017.05.044
Journal Energy and Buildings
Citation
Abdelalim, A. (Aly), O'Brien, W, & Shi, Z. (Zixiao). (2017). Corrigendum to “Visualization of energy and water consumption and GHG emissions: A case study of a Canadian University Campus” [Energy Build. 109 (2015) 334–352] (Energy and Buildings (S037877881530298X), (10.1016/j.enbuild.2015.09.058)). Energy and Buildings, 150. doi:10.1016/j.enbuild.2017.05.044